Public Inquiry

Ronan Point Inquiry

Completed · Chair: Hugh Griffiths QC · Established May 1968 · Commissioned by Ministry of Housing, Communities and Local Government

Inquiry into the partial collapse of Ronan Point tower block in Canning Town on 16 May 1968 following a gas explosion which killed four people.

Historical inquiry (pre-Inquiries Act 2005). Listed for reference; recommendation progress is not actively tracked.

Where it stands

Ronan Point Inquiry — Final Report was published on 6 November 1968.

This is a historical inquiry. Per-recommendation tracking is not available. See Legacy and impact below.

Record checked against the sources 27 February 2026.

Reports

Reports and timeline

Recommendations

18 shown

RONA-12: Strengthen Ronan Point and make the joints continuous

Recommended

Ronan Point should be strengthened, in particular by making the joints tougher and more continuous, so that local damage to the load-bearing walls from whatever cause will not lead to progressive collapse; and so that the building is capable of safely withstanding the maximum wind forces which it is likely to experience during its lifetime (paragraphs 131 and 145).

Addressed to no body recorded · Full record

RONA-20: Statutory notification and inspection of gas appliance installations

Recommended

In order to reduce the risk of town gas explosions still further, consideration should be given to a statutory requirement, based on the provisions of the London Gas Undertakings (Regulations) Act 1939, that the installation of any gas appliance should be notified to the area Gas Board, who should have a duty to inspect, and a power, if the installation were unsatisfactory, to refuse the supply of gas; inspection should preferably be free of charge (paragraph 169).

Addressed to no body recorded · Full record

RONA-29: Structural appraisal of all blocks over six storeys

Recommended

All blocks over six storeys in height should be appraised by a structural engineer who should consider: (a) whether they are susceptible to progressive collapse (paragraph 191); (b) whether they have been designed to resist adequately the maximum wind loadings which they may experience (paragraph 214); (c) their behaviour in the event of fire (paragraph 216).

Addressed to no body recorded · Full record

RONA-32: New blocks to be designed against progressive collapse

Recommended

Designers of new blocks must design the building so that it is not susceptible to progressive collapse, paying particular attention to introducing continuity at the joints and so disposing the load-bearing walls that alternative paths are provided in the event of local failure (paragraph 188).

Addressed to no body recorded · Full record

RONA-33: Use recent wind research pending the new loading Code

Recommended

Until the new wind loading Code is produced, designers should have regard to the results of recent research into the frequency and duration of high wind speeds, when calculating the wind loadings for which the blocks are to be designed (paragraph 214).

Addressed to no body recorded · Full record

RONA-36: Owners of tall non-system-built blocks to check wind loads

Recommended

Owners of tall post-war blocks (say over 100 feet high) that are not system-built should inquire into the wind loads for which the blocks were designed and seek professional advice as to the adequacy of their buildings to withstand the wind forces now known to be likely to act on them during their lifetimes (paragraph 214).

Addressed to no body recorded · Full record

RONA-47: Minister to keep Standards and Codes of Practice up to date

Recommended

The Minister of Housing and Local Government, who is responsible for the Building Regulations, must accept responsibility for seeing that the British Standards and Codes of Practice referred to in the Regulations are kept up to date, and that new ones are promulgated as necessary. Machinery should be devised to effect this (paragraph 217).

Addressed to no body recorded · Full record

Reports and timeline

Timeline

No milestones recorded.

Legacy & impact

AI-generated · 26 Mar 2026
The Ronan Point inquiry examined the partial collapse of a 22-storey tower block in Canning Town on 16 May 1968, following a gas explosion that killed four people. Chair Hugh Griffiths QC concluded that both the design and construction of the large panel system building were inadequate. The inquiry's 19 recommendations focused on preventing progressive collapse in high-rise buildings and managing explosion risks.

The inquiry's most significant documented legacy is the Building Regulations 1970 (5th Amendment), which introduced the concept of resistance to disproportionate collapse. This principle remains embedded in Part A of the current Building Regulations. The inquiry also led to the disconnection of piped gas from high-rise residential buildings and requirements for structural engineering assessments of buildings over six storeys.

The disaster effectively ended large panel system construction in the UK. However, when Ronan Point was demolished in 1986, investigators found structural joints packed with rubbish and that post-collapse strengthening works had been ineffective. This discovery raised questions about the implementation and enforcement of safety measures.

The Ronan Point inquiry occupies a significant place in the history of UK building safety regulation. Its focus on preventing disproportionate collapse established principles that continue to shape building standards. The 2017 Grenfell Tower fire renewed attention to questions about building safety regulation and enforcement that the Ronan Point inquiry had raised nearly five decades earlier.
Reforms attributed to this inquiry · AI-generated• Building Regulations 1970 (5th Amendment) introduced requirements for resistance to disproportionate collapse, now incorporated in Part A of the Building Regulations
• Disconnection of piped gas supplies from high-rise residential buildings
• Requirement for structural engineering appraisal of buildings over six storeys
• Effective end of large panel system construction methods in the UK
Unfinished business · AI-generated• No published evidence of formal implementation reviews of the inquiry's recommendations
• Recommendation for review of regulations governing storage of potentially explosive materials in high blocks (RONA-22)
• Recommendation for improved ventilation in flats in high blocks (RONA-21)
• Broader application of structural safety requirements to non-residential buildings over 100 feet (RONA-35)

Key legislation

Building Regulations 1970 (5th Amendment — Disproportionate Collapse) Primary
Introduced the concept of resistance to disproportionate collapse, now embedded in Part A of the Building Regulations.

Influence & connections

Informed or shaped Grenfell Tower Inquiry
Ronan Point introduced the concept of resistance to disproportionate collapse in building regulations. The Grenfell Tower fire raised the same fundamental question about the gap between building regulation and safety in practice.

Key facts

Duration: 5 months